The choice of power supply affects how an electromagnetic component is controlled and behaves in an application. The decision is often based on the power supply already available in the machine, but factors such as noise, heat, response time, and the installation environment also need to be taken into account.
AC stands for alternating current, while DC stands for direct current. Both create a magnetic field when electric current flows through a coil. The main differences lie in how the power supply behaves and how the product is designed to handle it.
It is not possible to say that one type is always stronger or faster than the other. Performance depends on the design, voltage, stroke length, and permitted duty cycle. Therefore, always check the datasheet for the specific model.
AC and DC solenoids operate on the same electromagnetic principle, but differences in performance arise because alternating current and direct current load the coil in different ways. Both AC and DC can provide reliable operation when the voltage, frequency, and operating conditions are matched to the solenoid.
The difference between direct current and alternating current
With direct current, electric charge flows in the same direction through the circuit. The term comes from the English phrase direct current. This type of power supply is commonly used in electronics, vehicles, battery-powered products, and automated control systems.
With alternating current, the direction of the current changes periodically. Mains power normally has a frequency of 50 Hz in Sweden and much of Europe. In other markets, 60 Hz is also used.
The key differences are shown below:
| Property | DC | AC |
|---|---|---|
| Current direction | Same direction | Alternating direction |
| Common voltages | For example, 12 or 24 V | For example, 110 or 230 V |
| Noise level | Usually low | May produce an audible hum |
| Battery operation | Directly possible | Normally requires conversion |
| Electronic control | Often easy to integrate | Requires AC-compatible control |
| Frequency requirement | No mains frequency requirement | Must match the product’s rated specifications |
| Blocked movement | Can cause mechanical failure and continued heating | Can result in particularly high heat generation |
The table shows typical characteristics, not rules that apply to every product.
How a DC solenoid works
When a DC solenoid is connected to a direct current power supply, the current begins to build up in the coil. The magnetic field acts on the iron core and causes the moving part to change position.
The steady-state current level is mainly limited by the resistance of the winding. During energization, the inductance also affects how quickly the current rises. This can be important in applications that require a fast response.
Common control methods are:
- Transistor output
- PLC output
- Electronic relay
- Mechanical relays
- Separate DC power supply
- Battery
When an inductive load is switched off, a voltage spike can occur. Electronic control circuits therefore normally require suitable protection, such as a flyback diode. The choice of protection can affect how quickly the force decays after power is removed.
DC solenoids are particularly useful when the system already operates at low voltage or needs to be battery-powered. Examples include vehicles, portable devices, and medical equipment.
Our range of linear solenoids includes models for several supply voltages.
How an AC solenoid works
An AC solenoid is connected to an alternating voltage supply. Because the supply alternates, the electromagnetic flux also changes over time. However, in a properly designed product, the force remains attractive.
When the moving core is far from the end position, the inrush current can be high. As the core is pulled in, the magnetic circuit changes and the current level normally decreases.
This means that a blocked core can cause problems. If it does not reach the end position, the elevated current level may persist and the unit may overheat. The mechanism must therefore be able to move freely.
An AC design can also produce hum and vibration. Some designs use an integrated shading ring, often made of copper, to reduce force pulsation as the supply voltage passes through zero. This copper ring helps provide a smoother holding force.
Make sure that the rated voltage and frequency are suitable for the installation. A product designed for a specific mains frequency should not be used at a different frequency unless supported by the manufacturer’s documentation.
AC vs. DC – differences in performance
Noise
DC designs are usually quieter because the magnetic flux becomes stable after energization.
AC designs can produce an audible hum. The noise level is affected by the design, mounting, wear, and whether the moving part reaches its intended position.
Heat
Both versions generate heat. The temperature rise is affected by voltage, activation time, ambient conditions, and duty cycle.
A DC model can become too hot if it is supplied with excessive voltage or energized for longer than permitted. An AC model is particularly sensitive if the movement is blocked before full engagement.
Control
DC products can often be controlled directly by modern electronics, provided that the output can handle the load and is protected against inductive voltage spikes.
An AC load can be controlled using a suitable relay, contactor, or solid-state solution. The control component must be rated for both the nominal voltage and the initial load.
Power
Some AC designs can provide a high pull-in force when energized, while DC models often provide a smoother and more easily controlled response. This does not mean that one technology generally produces greater force than the other.
The capacity must be verified at the actual stroke length. Read our guide on how to determine the required force.
Power supply in a solenoid valve
A solenoid valve consists of an electromagnetic actuator and a valve that controls gas or liquid. The choice of power supply affects actuation, while the valve body, seals, pressure, and flow determine the fluid-handling performance.
An AC solenoid valve can be suitable for a fixed installation where the correct AC supply is already available. A DC version may be more practical in a battery-powered machine or when used with electronic control.
Check:
- Rated voltage
- Pressure and temperature
- Normally open or normally closed function
- Permissible activation time
- Control system capacity
- Environmental and IP requirements
Elektrokomponenter’s product range is primarily focused on solenoids and electromagnets rather than complete solenoid valves.
Conversion between the two types of power supply
Using a rectifier, alternating current can be converted to direct current before the load is supplied. The rectifier can be built in or installed externally.
However, rectification does not solve every sizing issue. The output voltage, ripple, power capacity, and protection must also be suitable for the product.
If an AC load is to be powered from a battery, an inverter is required instead. Each additional conversion stage introduces power losses, requires space, and adds more components.
In battery-powered systems, battery capacity, charging, and the expected activation time must also be included in the calculation.
When is DC operation suitable?
Normally choose this solution when:
- The machine already has a 12 or 24 V DC supply
- The function is controlled by a PLC or transistor
- Battery operation is required
- Low noise levels are important
- Electronic control is to be used
- The system is installed in a vehicle or mobile unit
For applications that need to maintain a position for an extended period, latching solenoids can be energy-efficient. They can hold their position without continuous power.
When is AC operation suitable?
This option is often suitable when:
- The machine already has the correct mains supply
- Direct connection simplifies the installation
- The control system is designed for AC voltage
- The product’s rated specifications match the application
- A separate DC power supply would complicate the system
In demanding environments, the inrush current, frequency, and risk of blocked movement also need to be assessed. See our industrial solenoids for different designs.
Checklist before making your selection
Check the following:
- What power supply is already available in the machine?
- What voltages can the control system handle?
- Is battery operation required?
- Are there requirements for low noise levels?
- How long is the activation time?
- How often is the function activated?
- What force is required at the starting position?
- Is rapid de-energization required?
- What should happen in the event of a power failure?
Then check the voltage, power, stroke length, and duty cycle in the datasheet. Do not select a model solely because the power supply happens to match.
Also read How to choose the right solenoid for a complete overview of the sizing process.
Need help choosing the right power supply?
Send us information about the available power supply, required force, stroke length, activation time, and installation environment. We can help you compare models and determine whether a standard product or a customized solution is the best fit.