Guide to IP Ratings – Choose the Right IP Rating

Vattentät solenoidprovning med IP-skydd

An enclosure rating indicates how well an electrical product is protected against contact, solid objects, dust, and water. Choosing the right level is especially important when a solenoid is used in industrial environments, outdoors, or in equipment that is cleaned regularly.

A higher number is not automatically the best choice. Base your selection on the actual exposure, installation conditions, and the product’s complete documentation.

Different IP ratings provide different levels of protection against solid objects and water. The IP rating indicates which tests the product enclosure has passed.

What does IP mean?

IP stands for Ingress Protection. The system is defined in the IEC 60529 standard and indicates the level of protection against the ingress of solid objects and liquids.

The rating consists of two digits. For example, in IP54, the first digit, 5, indicates the level of protection against solid particles, while the second digit, 4, indicates the level of protection against water.

However, the code does not normally indicate protection against:

  • corrosion
  • chemicals
  • oil
  • UV radiation
  • extreme temperatures
  • vibration
  • mechanical impact
  • explosive atmospheres

Such requirements must be assessed separately.

First digit – solid objects

The first digit indicates how well the enclosure prevents solid objects from reaching sensitive or hazardous parts.

LevelMeaning
0No specified protection
1Objects larger than 50 mm
2Objects larger than 12,5 mm
3Objects larger than 2,5 mm
4Objects larger than 1 mm
5Dust-protected
6Dust-tight

At level 5, a limited amount of dust may enter, but not enough to impair operation. Level 6 means that the enclosure is completely dust-tight according to the applicable test.

Second digit – protection against water

The second digit indicates the type of water exposure the product has been tested for.

LevelMeaning
0No protection against water
1Vertically dripping water
2Dripping water when the enclosure is tilted
3Spraying water within specified angles
4Splashing water from all directions
5Water jets
6Powerful water jets
7Temporary immersion
8Prolonged immersion under specified conditions
9High-pressure, high-temperature water jets

Test conditions and exposure time are important. Therefore, always read the datasheet instead of comparing the numbers alone.

Lower IP ratings

Lower ratings are mainly used in protected environments:

  • IP20: protection against contact, but no protection against water
  • IP21: also protected against dripping water
  • IP23: withstands spraying water within specified angles
  • IP24: withstands splashing water from all directions

These ratings are not dust-tight. They may be suitable inside a machine or enclosure where the outer housing provides additional protection.

IP44 – solid objects and splashing water

IP44 provides protection against objects larger than 1 mm and against water splashes from different directions.

This rating may be sufficient in a protected environment with limited moisture. However, it is not intended for powerful water jets or underwater use.

What does IP40 mean?

A product with an IP40 rating has:

  • protection against solid objects larger than 1 mm
  • no specified protection against water

This may be sufficient inside a dry, enclosed machine where water cannot enter.

B12 is an example of a locking bolt rated IP40.

What does IP54 mean?

IP54 means that the product is dust-protected and can withstand water splashes from different directions.

It is a common rating in industrial installations where limited amounts of dust and moisture are present. However, the component should not be exposed to powerful water jets or used underwater.

B24 is specified with an IP54 rating.

The connector and cable entry must provide an equivalent level of sealing. Otherwise, the actual protection level of the installation may be lower.

What does IP65 mean?

IP65 means that the enclosure is dust-tight and protected against water jets.

This rating may be suitable for dirty industrial environments or applications involving regular washdowns. However, it does not automatically mean that the product can withstand:

  • high-pressure cleaning
  • hot water
  • aggressive cleaning agents
  • underwater use

Check the pressure, distance, temperature, and exposure time in the documentation.

What does IP67 mean?

IP67 means that the product is dust-tight and has been tested for temporary immersion in water under specified conditions.

This is not the same as permanent underwater operation. The rating also does not automatically include protection against water jets according to IP65 or IP66. If both types of exposure occur, the datasheet must explicitly support them.

The product must not be submerged for extended periods if the documentation only specifies level 7. Long-term immersion in water requires a rating and testing that explicitly covers this.

How to Choose the Right Rating

Assess the environment before selecting a product.

Dust and solid particles

Determine:

  • whether fine dust is present in the air
  • whether metal chips or fibers can reach the unit
  • whether the product is installed inside an enclosure
  • whether dirt can block the moving part
  • how often the installation is cleaned

For exposed environments, you can view our range of industrial solenoids.

Moisture and water

Assess whether the equipment is exposed to:

  • condensation
  • dripping water
  • splashes
  • washdown
  • high-pressure cleaning
  • temporary flooding

Condensation can occur even without direct contact with water. Rapid temperature changes and high humidity may therefore require additional protective measures.

Chemicals and corrosion

The IP rating does not indicate chemical resistance. If the environment contains salt, oil, solvents, or cleaning agents, the materials and seals must be assessed separately.

Check:

  • enclosure material
  • surface treatment
  • seals
  • contact materials
  • cable resistance

A product may have good sealing and still be unsuitable for a corrosive environment.

Temperature

The coil generates heat during operation. Therefore, check both the ambient temperature and the product’s permitted operating conditions.

Read more in the guide How to Interpret a Solenoid’s Duty Cycle.

Mounting

The rating applies when the unit is installed according to the manufacturer’s instructions. Incorrect mounting orientation, damaged gaskets, or a loosely tightened connector can reduce the level of sealing.

Check:

  • mounting orientation
  • gaskets
  • cable entry
  • connectors
  • screw connections
  • need for drainage
  • risk of standing water

The entire installation must maintain the same level of protection.

The product’s rating does not automatically apply to the entire system. The final level of protection may be limited by:

  • connector
  • cable
  • cable gland
  • junction box
  • exposed mechanical parts
  • mounting surface

An IP65-rated unit connected with an IP40 connector does not automatically result in an IP65 installation.

Outdoor use requires a broader assessment

For outdoor installation, you also need to consider:

  • rain and wind-driven rain
  • condensation and frost
  • UV radiation
  • temperature variations
  • salt and air pollution
  • standing water

A suitable IP rating does not guarantee resistance to corrosion, sunlight, or frost. An external enclosure, drainage, and protected placement may still be necessary.

IP rating is not explosion protection.

A high IP rating does not mean that the product is approved for use in potentially explosive atmospheres.

Where flammable gas, vapor, or fine dust may be present, a separate risk assessment and relevant certification are required. Use only components that are explicitly intended for the specific environment.

Practical examples

Dry machine environment

The product is installed inside an enclosed machine in a clean environment.

Possible starting point: IP20 or IP40, provided that the machine enclosure provides the necessary protection.

Dusty industrial environment

The unit is exposed to dirt and limited splashing.

Possible starting point: IP54 or higher, depending on the cleaning method and the amount of particles.

Regular washdown

The equipment is cleaned using water jets.

Possible starting point: IP65 or IP66. Check the pressure, temperature, distance, and cleaning agents.

Risk of flooding

The product may be temporarily submerged in water.

Possible starting point: level 7, provided that the test conditions correspond to the actual situation.

These examples are for guidance only and do not replace a risk assessment.

Vanliga fel

Avoid:

  • choosing a rating based solely on the highest number
  • assuming that level 7 automatically includes protection against water jets
  • forgetting the cable and connector
  • equating sealing with corrosion resistance
  • overlooking condensation
  • assuming that level 5 always withstands high-pressure cleaning
  • using the IP rating as explosion protection
  • ignoring the installation instructions

Common mistakes

Is a higher rating always better?

No. More extensive sealing can affect price, size, cooling, and installation. The correct choice should match the actual environment.

What does X mean in, for example, IPX5?

X means that no value is specified for that position. IPX5 specifies water protection at level 5, but does not specify protection against solid objects.

Does the rating apply to the entire installation?

Not automatically. The cable, connector, seals, and installation must provide an equivalent level of protection.

Does a water rating mean that the product can withstand chemicals?

No. Resistance to oils, solvents, and cleaning agents must be checked separately.

Checklist for product selection

Compile the following information:

  • presence of particles
  • type of water exposure
  • cleaning method
  • ambient temperature
  • risk of condensation
  • chemicals and corrosion
  • indoor or outdoor installation
  • connector and cable type
  • mounting orientation
  • certification requirements

In our product catalog, you will find models with different protection ratings and technical specifications.

For a broader overview of force, stroke length, power supply, and environmental conditions, you can read How to Choose the Right Solenoid.

Need help choosing the right level of protection?

Describe the installation environment, water exposure, temperature, and mounting conditions. We will help you assess the requirements and determine whether a standard product or a customized solution is the best fit.

Contact Elektrokomponenter