How Do You Calculate the Required Force for a Solenoid?

industriell solenoid

To select the right solenoid, you need to know how much force is required in the specific application. It is rarely enough to consider only the weight of the part being moved. Friction, springs, acceleration, pressure differences and mounting orientation can also affect the total load.

It is important to distinguish between the force required by the application and the force the product can generate. The required force can be estimated based on the mechanics of the application, while the product’s available force normally needs to be verified using a force–stroke curve or datasheet.

In this guide, we explain how to calculate the required load and how to use the result to compare different solenoids.

How a Solenoid Generates Magnetic Force

A solenoid is an electromechanical component that converts electrical energy into motion. It contains a wound coil and a moving core made of ferromagnetic material.

When electric current passes through the coil, a magnetic field is generated. This attracts the core towards a position where the resistance of the magnetic circuit is lower. The movement can be used to release a lock, actuate a valve or move a mechanism.

The same principle of magnetism is used in several technical applications, including relays, actuators, motors and starter motors. For the system to operate reliably, the windings, control system and power supply must be matched to the correct voltage and current level in amperes.

The force is influenced by factors including:

  • the current through the solenoid
  • the number of turns in the winding
  • the coil geometry and diameter
  • the core material
  • the distance between the core and pole
  • magnetic saturation
  • mechanical friction

The available force is therefore not constant throughout the entire movement. It is often lower when the distance is large and higher as the moving part approaches its end position.

Basic Formula for the Application’s Force Requirement

The required force can be described in simplified terms as the sum of the opposing forces that must be overcome:

F_\text{last}
+
F_\text{friktion}
+
F_\text{fjäder}
+
F_\text{acceleration}
+
F_\text{tryck}
]

The result is then multiplied by a safety factor:

F_\text{behov}\times S
]

Where (S) is the safety factor. A common starting value may be 1.3–2.0. The appropriate level depends on variations, wear, environmental conditions and the consequences of the function failing to activate.

The safety factor should not be used to compensate for an uncertain initial calculation. First, identify all the forces that affect the movement.

1. Force Required to Accelerate a Mass

If the unit needs to set a mass in motion, Newton’s second law is used:

[
F=m\times a
]

Where:

  • (F) is the force in newtons
  • (m) is the mass in kilograms
  • (a) is the acceleration in metres per second squared

A mass of 2 kg that needs to be accelerated at 0.5 m/s² requires:

[
F=2\times0,5=1\ \text{N}
]

This is only the acceleration force. Friction, gravity and other opposing forces must also be taken into account.

If the movement is slow, this component may be small. In fast automated machines, it can become more significant.

2. Friction in the Mechanism

Friction can occur in plain bearings, seals, linkages, guides and other contact surfaces. For a simple sliding load, the friction force can be estimated using:

[
F_\text{friktion}=\mu\times N
]

Where:

  • (\mu) is the coefficient of friction
  • (N) is the normal force

In practical designs, friction is not always easy to determine. Seals, for example, may have higher breakaway friction than friction during continuous movement. Dirt, corrosion and manufacturing tolerances can also affect the result.

Whenever possible, the actual load should be measured in a prototype or existing mechanism. Measure at the most demanding position and under realistic conditions.

3. Spring Force

If the movement acts against a spring, its opposing force must be included. For an ideal linear spring, Hooke’s law is used:

[
F_\text{fjäder}=k\times x
]

Where:

  • (k) is the spring constant in N/mm
  • (x) is the spring displacement in mm

A spring with a spring constant of 2 N/mm that is compressed by 5 mm produces:

[
F_\text{fjäder}=2\times5=10\ \text{N}
]

If the spring is already preloaded, the preload force must be added. The load may therefore differ at the beginning and end of the movement.

Some linear solenoids can be fitted with a return spring or push rod depending on the required function.

4. Gravity in Vertical Movement

If a mass is to be lifted vertically, the force of gravity must be overcome:

[
F_\text{gravitation}=m\times g
]

Where (g) is approximately 9.81 m/s².

For a mass of 2 kg, the force is:

[
F_\text{gravitation}=2\times9,81=19,62\ \text{N}
]

When moving downward, gravity can instead assist the movement. However, the design must still account for what happens in the event of a power failure and whether the load needs to be held securely in a fixed position.

5. Pressure force in a solenoid valve

In a solenoid valve or other pressurized mechanism, the medium can create a counterforce:

[
F_\text{tryck}=\Delta p\times A
]

Where:

  • (\Delta p) is the pressure difference in pascals
  • (A) is the affected area in square meters

The pressure force can become significant even over a small area. The valve design, seals, and flow direction therefore also need to be taken into account.

A solenoid and a complete solenoid valve are not the same product. The former creates the electromagnetic motion. The latter also includes the valve body, seals, and flow paths that affect the load.

Practical calculation example

Assume that a product is intended to move a horizontal mechanism under the following conditions:

  • Acceleration force: 1 N
  • Measured breakaway friction: 8 N
  • Spring force at startup: 12 N
  • No force from gravity or fluid pressure

The total force requirement is:

[
F_\text{behov}=1+8+12=21\ \text{N}
]

With a safety factor of 1.5, the design force becomes:

[
F_\text{dimensionerande}=21\times1,5=31,5\ \text{N}
]

The selected model must therefore be able to provide at least 31.5 N at the actual starting distance. If the motion begins with an 8 mm air gap, the force should be verified at 8 mm, not only at the end position.

This is a common sizing mistake. A product may have sufficient maximum force but still be too weak at the point where the movement begins.

Theoretical estimation of magnetic force

For an idealized system, the force across an air gap can be estimated using:

[
F\approx\frac{B^2A}{2\mu_0}
]

Where:

  • (F) is the force in newtons
  • (B) is the magnetic flux density in teslas
  • (A) is the pole-face area
  • (\mu_0) is the permeability of free space

The formula shows that the result is strongly influenced by both the magnetic field level and the area. However, it is only a simplified estimate.

In real electromagnets, leakage flux, varying air gaps, material saturation, and losses all occur. The magnet and iron core also do not behave linearly at all operating levels. Therefore, this formula should not be used as the sole basis for product selection.

For off-the-shelf components, the manufacturer’s measured force curve is generally more reliable than a theoretical model.

How does the solenoid’s inductance affect performance?

When voltage is applied, the current does not immediately rise to its final value. How quickly it does so depends on the relationship between \(L\) and the circuit resistance:

[
\tau=\frac{L}{R}
]

The electrical time constant can affect how quickly sufficient force is built up. In practice, the characteristics also change as the core moves to a different position.

Always follow the datasheet specifications for supply voltage and activation time. A 12 V or 24 V DC model should be powered according to its rated voltage.

The relationship between force and stroke length

One of the most important factors is the relationship between force and the starting position. In many designs, the force decreases rapidly as the distance from the end position increases.

When comparing models, you need to know:

  1. Required total stroke length
  2. The load’s force requirement at startup
  3. The force requirement throughout the entire movement
  4. Available force at each relevant position

Do not select a product based solely on its value at the end position. Also read the guide How to choose the right solenoid for more sizing factors.

Force, operation, and service life

Rated specifications apply under defined conditions. A higher current can temporarily produce a stronger magnetic field, but it also increases heat generation. The product must therefore not be overloaded to compensate for insufficient force.

Check:

  • Rated voltage
  • Duty cycle
  • Maximum activation time
  • Ambient environment
  • Number of activations
  • Permissible temperature rise

For applications where a position needs to be maintained for an extended period, latching solenoids can reduce energy consumption. They use a permanent magnet to maintain the position without continuous power.

For demanding conditions, you can also explore our range of industrial solenoids.

Common sizing mistakes

Above all, avoid the following mistakes:

  • Using the maximum force without checking the starting position
  • Forgetting breakaway friction and seals
  • Failing to account for spring preload
  • Ignoring gravity in vertical movement
  • Ignoring pressure force in a valve
  • Using too small a safety margin
  • Trying to compensate for insufficient force with excessive supply voltage
  • Failing to verify the result through practical testing

Another common mistake is confusing newtons with kilograms. Kilograms indicate mass, while force is normally expressed in newtons. One kilogram-force is approximately equal to 9.81 N.

Information needed to select a model

Compile the following information before searching our product catalog:

  • Design force in newtons
  • Stroke length
  • starting position or air gap
  • available voltage
  • Pull or push function
  • Activation time and frequency
  • mounting orientation
  • Ambient environment
  • Desired position without power

If a standard model does not meet the requirements, aspects such as voltage, wiring, mounting, plunger connection, and push rod can be customized. Read more about our customized solutions.

Need help determining the required force?

Send us details about the load, stroke length, spring force, friction, voltage, and operating frequency. Also specify whether the movement is horizontal or vertical and whether the system is affected by pressure.

We can help you assess your requirements and find a suitable standard model or customized solution.

Contact Elektrokomponenter