The duty cycle is crucial when selecting a solenoid. It describes how much of an operating period the component may be energized and how long it needs to cool down between activations.
A model with a low duty cycle can sometimes generate high force for a short period. However, the same model may overheat if it remains activated for too long. Therefore, it is not enough to check only the voltage, force, and stroke length.
In this guide, we explain the difference between continuous and intermittent operation, show how the duty cycle is calculated, and review common sizing mistakes.
The solenoid generates heat when the coil is energized, which makes the ratio between activation time and rest time important.
What is a duty cycle?
Duty cycle, or intermittency, refers to the ratio between the time the coil is energized and the total operating period.
It is calculated as:
[
ED = \frac{t_\text{on}}{t_\text{on} + t_\text{off}} \times 100
]
Where:
- (ED) is the duty cycle as a percentage
- (t_on) is the time the coil is energized
- (t_off) is the rest time without power
If the unit is activated for 20 seconds and then switched off for 80 seconds, the result is:
[
ED = \frac{20}{20 + 80} \times 100 = 20%
]
The duty cycle is therefore 20 percent.
This does not automatically mean that all 20% duty cycle models may remain energized for 20 seconds. The manufacturer may also specify a maximum continuous energization time and a defined reference period.
Continuous and intermittent operation
Continuous operation – 100%
A solenoid rated for a 100% duty cycle is designed to remain continuously energized under the conditions specified in the datasheet.
This assumes, among other things:
- the correct supply voltage
- an allowable ambient temperature
- correct installation
- sufficient heat dissipation
- an undamaged coil
- that the rated values are not exceeded
Continuous operation does not mean that the component remains cool. The temperature rises until the heat generated equals the heat dissipated to the surroundings.
If the environment is warmer or ventilation is poorer than under the specified conditions, the final temperature may be higher.
Intermittent operation
A model designed for intermittent operation is intended to be energized for a limited period and then allowed to cool down.
Common ratings may include, for example:
- 40 %
- 25 %
- 15 %
- 10 %
- 5 %
A lower percentage normally means that the activation time must be shorter relative to the rest time.
In some product series, intermittent-duty models may use higher power to generate greater force for a short period. They must therefore not be used continuously unless the datasheet explicitly permits it.
Different solenoids may have different allowable energization times even if they have the same external dimensions and supply voltage.
Three practical calculation examples
Example 1: 50% duty cycle
The unit is activated for 30 seconds and switched off for 30 seconds:
[
ED=\frac{30}{30+30}\times100=50%
]
Example 2: 25% duty cycle
The unit is activated for 15 seconds and switched off for 45 seconds:
[
ED=\frac{15}{15+45}\times100=25%
]
Example 3: 10% duty cycle
The unit is activated for 3 seconds and switched off for 27 seconds:
[
ED=\frac{3}{3+27}\times100=10%
]
These examples illustrate the calculation, but they do not replace the product specification. Two operating cycles can have the same duty cycle percentage but result in different temperature development.
An activation time of 6 minutes followed by 54 minutes of rest also results in a 10% duty cycle, but it may still be prohibited if the maximum continuous energization time is shorter.
The duty cycle must be tied to a specific time period.
A percentage without a time reference does not provide the full picture.
Compare:
- 1 second on and 9 seconds off
- 10 seconds on and 90 seconds off
- 1 minute on and 9 minutes off
All correspond to a 10% duty cycle, but the coil may reach different temperatures. During the longer activation period, more heat has time to build up before the rest period begins.
Therefore, always check:
- specified duty cycle
- reference period
- Maximum activation time
- required rest time
- whether the rating applies from a cold or warm state
- an allowable ambient temperature
If this information is missing, you should ask the supplier for clarification.
Why does the coil get hot?
When current passes through the winding, heat is generated. The electrical power loss can be simplified as:
[
P=I^2R
]
Where:
- (P) is the power loss
- (I) is the current
- (R) is the resistance of the winding
Because the current is squared, an increase can have a significant effect on heat generation.
As the copper winding heats up, its resistance normally increases. At a constant voltage, the current may then decrease, which can also affect the available force.
The temperature is also affected by:
- the material and size of the enclosure
- the mounting surface
- airflow
- nearby heat sources
- ambient temperature
- Number of activations
- the ratio between on-time and off-time
A metal mounting surface can, in some cases, help dissipate heat, while an insulating or enclosed installation can reduce cooling.
The voltage must be correct
The duty rating applies at the product’s specified voltage and electrical conditions. A voltage higher than the rated value can increase the current and heat generation.
Overvoltage should not be used as a simple way to obtain more force. It can lead to:
- overheating
- damaged insulation
- shorter service life
- altered force values
- permanent component failure
Therefore, always check the voltage, power, and duty cycle together.
If you are comparing power supply options, you can read AC solenoid compared with DC solenoid.
How does the duty cycle affect force?
In some product series, the same mechanical size is available with different windings or power ratings. A version designed for short activation periods may therefore generate more force than a version intended for continuous operation.
This means that two models with the same external dimensions and stroke length can have different:
- power
- current
- force
- Permissible activation time
- heat generation
Do not choose the most powerful version without checking how long it may remain energized.
The force must also be verified at the actual working position. Read more in the guide Solenoid force and stroke length – how to size correctly.
Cold and hot conditions
A unit starting at room temperature operates under different conditions than one that is already warm after repeated activations.
During cyclic operation, the temperature may gradually rise until thermal equilibrium is reached. This means that the first few cycles do not always represent long-term operation.
When testing, you should therefore check:
- operation from a cold state
- operation after warm-up
- force at the highest expected temperature
- recovery during the rest period
- temperature in the actual installation
Test with the actual mechanical load and the planned control system. A no-load test does not always provide enough information about the finished application.
The number of cycles is a separate consideration
Duty cycle and mechanical service life are not the same thing.
A unit can have a low duty cycle and still be activated very frequently. For example, short pulses may be repeated thousands of times during a working day. This can place stress on:
- sliding surfaces
- springs
- couplings
- stop surfaces
- electrical contacts
- the connected mechanism
The expected number of cycles therefore needs to be evaluated separately from the thermal load.
If the application requires both a high activation frequency and a long service life, the product should be tested under representative conditions.
When is a latching solenoid suitable?
If a position needs to be maintained for a long time, a latching solenoid can be an energy-efficient alternative.
It uses a permanent magnet to hold the active position after a short electrical pulse. Continuous power is therefore not required to maintain the position.
This can provide:
- lower energy consumption
- less heat generation
- longer battery life
- lower continuous load on the control system
On many latching models, a reverse-polarity pulse is used to release the mechanism. Always verify the function in the product datasheet. The operating principle must therefore match the system’s requirements in the event of a power failure or other fault condition.
Example of sizing
Assume that a locking mechanism is to be activated as follows:
- On-time: 2 seconds
- Off-time: 18 seconds
- 180 activations per hour
- Power supply: 24 V DC
- Ambient temperature: 35 °C
The duty cycle is:
[
ED=\frac{2}{2+18}\times100=10%
]
A model rated for at least a 10% duty cycle may be suitable, but the following still need to be verified:
- Is a continuous activation time of two seconds permitted?
- Does the rating apply at 35 °C?
- Can the product handle 180 cycles per hour?
- Does it provide sufficient force after warming up?
- Can the installation dissipate the heat?
- What happens if the mechanism becomes blocked?
The percentage value is therefore only one part of the sizing process.
Common mistakes
Avoid the following:
- Interpreting 10% as allowing any on-time within an hour
- Ignoring the maximum activation time
- Using an intermittent-duty model continuously
- Increasing the voltage to obtain more force
- Testing only from a cold state
- Overlooking the ambient temperature
- Ignoring heat from nearby components
- Confusing duty cycle with the number of mechanical cycles
- Selecting a model without checking the force at the correct stroke length
- Assuming that a larger enclosure will always solve the heat problem
Checklist for product selection
Compile the following information:
- supply voltage
- on-time
- off-time
- duty cycle
- maximum continuous activation time
- number of cycles per hour
- ambient temperature
- mounting method
- available force at the operating position
- required position in the event of a power failure
- service life requirements
Use this information together with the product datasheet. In our product catalog, you will find models with different voltages, power ratings, and operating modes.
For a broader overview, you can also read How to choose the right solenoid.
Need help choosing the right duty rating?
Send us information about the voltage, on-time, off-time, activation frequency, force requirements, and installation environment. We will help you determine which duty rating is suitable and whether you need a standard model or a customized solution.