Solenoid Force and Stroke Length – How to Choose the Right Size

slaglängd kraft solenoid

Force and stroke length are two of the most important characteristics to consider when selecting a solenoid. They must always be evaluated together. A model that can generate sufficient force near the end of its stroke may be considerably weaker at the point where the movement begins.

Therefore, it is not enough to compare maximum force or maximum possible stroke length. You need to know how much force is available at each relevant position throughout the movement.

In this guide, we explain the relationship between force, stroke length, and air gap, and show you how to use a force–stroke curve to select the right model.

What does stroke length mean?

Stroke length is the distance that the solenoid’s moving core or plunger travels between two positions. It is usually specified in millimetres.

The required stroke length is determined by the function to be performed. For example, it may involve:

  • release a lock
  • move a mechanical stop
  • actuate a valve
  • press a switch
  • move a bolt into position
  • move a linkage or lever

Base your selection on the actual movement required by the mechanism. Do not add extra stroke length without a specific reason. A longer stroke may require a larger product and can reduce the amount of force available at the starting position.

Our range of linear solenoids includes models with different stroke lengths and mechanical designs.

Why does the force change during the movement?

When electric current passes through the coil, a magnetic field is generated that attracts the moving iron core. The distance between the core and the fixed magnetic component is often referred to as the air gap.

In many pull-type designs, the following applies:

  • a large air gap results in lower force
  • a smaller air gap results in higher force
  • maximum force is normally achieved near the end position

This means that the solenoid is often at its weakest just as the movement begins. This is also when the load may require the most force due to static friction, a preloaded spring, or mechanical resistance.

The exact force profile depends on the product’s geometry, voltage, current, and magnetic design. Therefore, always refer to the manufacturer’s documentation when available.

Maximum force can be misleading.

A stated maximum value does not necessarily indicate how much force is available throughout the entire stroke. The value may apply to:

  • near the mechanical end position
  • at a specified voltage
  • at a certain duty cycle
  • under specified temperature conditions
  • for a specific version of the product

Also check what type of force is specified. On an electric locking bolt, for example, the maximum radial locking force may be entirely different from the force used to move the bolt itself.

Produktsidan för B24 anger både maximal radiell kraft och kolvens in- och utgående kraft. Dessa värden beskriver olika funktioner och får inte användas som om de vore samma sak.

Therefore, always ask:

What force does the product provide at the position where my movement begins?

How to Read a Force–Stroke Curve

A force–stroke curve shows how the available force changes with the position of the moving part.

Typically, the following are shown:

  • stroke length or air gap on the horizontal axis
  • force in newtons on the vertical axis
  • one or more curves for different power ratings or duty classes

To use the curve:

  1. Determine the stroke position where the movement begins.
  2. Locate this position on the horizontal axis.
  3. Read the available force from the relevant curve.
  4. Compare the value with the application’s design force requirement.
  5. Also check the force at other critical positions.

If the model is available in several duty classes, make sure to use the correct curve. A version designed for short-term operation may sometimes produce higher force than one intended for continuous duty, but it must not remain energized longer than specified.

Calculate the Design Force Requirement

Before comparing force curves, you need to know the total load.

Den kan förenklat beskrivas som:

F_\text{last}
+
F_\text{friktion}
+
F_\text{fjäder}
+
F_\text{acceleration}
+
F_\text{tryck}
]

Then add an appropriate safety margin:

F_\text{behov}\times S
]

where \(S\) is the safety factor.

If the total load is 25 N and the safety factor is 1.5, the required force is:

[
25\times1,5=37,5\ \text{N}
]

Anta att rörelsen börjar vid 10 mm luftgap. Den valda modellen måste då ge minst 37,5 N vid 10 mm – inte bara uppnå detta värde nära slutläget.

A more detailed calculation method is available in our guide How do you calculate the force requirement for a solenoid?.

Take the Spring Force into Account Throughout the Entire Stroke

If the mechanism operates against a spring, the load changes during the movement. For a linear spring, the force increases in proportion to the compression:

[
F=k\times x
]

Where:

  • (k) is the spring constant
  • (x) is the spring compression

This means that the load may increase at the same time as the solenoid’s available force changes. Therefore, do not compare only the values at the start and end positions. Check whether the force curve and the load curve approach or cross each other at any point during the movement.

If the available force falls below the opposing force, the movement may stop before the mechanism reaches its intended position.

Do not forget any preload. A return spring may exert force even before the movement begins.

Check Both Pulling and Pushing Operation

A solenoid can perform either a pulling or pushing motion. In a push-type design, the electromagnetic force is still generated by pulling the core inward, but the motion is transmitted through a push rod to the opposite side.

It is therefore important to check:

  • which side should be connected to the load
  • whether a push rod is required
  • how much travel is required
  • whether the load causes side forces
  • which position the mechanism should assume when de-energized

Avoid radial loads on the moving part. Side forces can increase friction, cause wear, and reduce the actual force below the expected level.

For an overview of direction of movement, voltage, and environmental requirements, read How to Choose the Right Solenoid.

Voltage and Duty Cycle Affect the Force

The force generated is affected by the current flowing through the coil. However, this does not mean that you can simply increase the voltage to obtain more force.

Excessive voltage or an excessively long energization time can cause:

  • overheating
  • damage to the coil insulation
  • reduced service life
  • altered force values
  • permanent product failure

Always use the rated voltage and duty cycle specified in the datasheet. If a model is available in several duty classes, select the version that matches the actual operating conditions.

The differences between the power supply options are explained in more detail in AC Solenoid vs. DC Solenoid.

Temperature Can Affect Performance

As the coil heats up, the electrical resistance of the copper winding normally increases. At a constant voltage, this can cause the current and the available force to decrease.

A force curve measured with a cold coil may therefore not exactly reflect the performance after prolonged operation.

When sizing the solenoid, you should know:

  • ambient temperature
  • energization time
  • Number of activations
  • ventilation
  • heat from nearby components
  • whether the force requirement applies immediately or after warm-up

In applications with small force margins, the difference between cold and warm operating conditions can be important.

Speed and Moving Mass

Sufficient static force does not automatically mean that the movement will be fast enough. The actuation time is also affected by:

  • moving mass
  • mechanical load
  • springs
  • friction
  • voltage and current build-up
  • stroke length

A heavy core or connected mechanism requires more energy to accelerate. A longer movement will also normally take more time to complete.

If the application requires fast or precise timing, the response time should be verified in practice using the actual load and control system.

Practical Sizing Example

Assume that a mechanism has the following requirements:

  • Required movement: 8 mm
  • Total load at the start: 18 N
  • Maximum load during the movement: 22 N
  • Safety factor: 1.5
  • Power supply: 24 V DC
  • Intermittent operation

The design force requirement is:

[
22\times1,5=33\ \text{N}
]

The model therefore needs to provide at least 33 N at the position where the load is highest.

If the force–stroke curve shows 35 N at 8 mm, there is only a small margin. Variations in voltage, friction, and temperature rise may then cause problems. A model with a larger margin, or a mechanical redesign, may be a safer choice.

For example, it may be possible to:

  • reduce the spring force
  • reduce friction
  • shorten the stroke
  • move the operating point closer to the end position
  • use a lever
  • choose a larger model

The goal is not always to choose the largest product, but to create a robust combination of electromagnetic force and mechanical design.

Common Mistakes When Selecting Stroke Length

Above all, avoid the following mistakes:

  • Selecting a model based on maximum force
  • Failing to check the force at the starting position
  • Confusing holding force with actuation force
  • Choosing a longer stroke than the function requires
  • Failing to account for spring preload
  • Forgetting friction and side loads
  • Using the wrong force curve or duty class
  • Failing to account for heating
  • Having insufficient safety margin
  • Failing to test with the actual load

Force and Stroke Length Checklist

Compile the following information:

  • actual stroke length
  • starting position or air gap
  • force requirement at the start
  • maximum force requirement during the movement
  • spring force and preload
  • friction
  • moving mass
  • desired actuation time
  • supply voltage
  • Duty cycle
  • ambient temperature
  • appropriate safety margin

Then use the correct force–stroke curve to verify that the model provides sufficient force throughout the entire operating range.

You can find the available product families in our product catalogue. If a standard model is not suitable, parameters such as voltage, mounting, push rod, spring, and plunger connection can be customized. Learn more about our customized solutions.

Need help sizing the right solenoid?

Send us information about the required stroke length, force requirement, voltage, duty cycle, and available installation space. Feel free to include a sketch or description of the mechanism.

We can help you assess the operating conditions and find a suitable standard model or customized solution.

Contact Elektrokomponenter