B30
Area of application:
Locking of guards on hazardous machinery and safety stop on lifts and lifting platforms in accordance with EN 60947-5-1. The shot bolt is energized to unlock. The built-in spring ensures that the bolt returns to the locked position when the power is interrupted. An internal positive opening contact provides position detection when the shot bolt is activated.
Maximum radial force: 15 000 kg
Piston output and input force: 2 kg
Stroke length: 30 mm
Standard voltage: 24 V DC – 230 V AC (–10%, +5%)
Possible voltages: 12 V – 220 V DC / 110 V – 230 V AC (–10%, +5%)
Power: DC = 75 W
Operating mode: Intermittent operation
Return spring: Internal
Position monitoring: NC safety switch (positive opening)
Protection: IP54
Total weight: 5.5 kg
Operating temperature: –5 °C to +40 °C
Temperature class: B
Dimensions (mm): 90 × 119 × 242
According to standard: EN 60947-5-1